10, 11, 12-WAY DIVIDER/COMBINER
10, 11, 12-WAY
PART NUMBER
FREQUENCY RANGE
(MHz)
INSERTION LOSS
(dB) Max.
ISOLATION (dB)
Min.
VSWR
In/Out
Max.
AMPLITUDE
BALANCE
Max.
PHASE
BALANCE
Max.
PL10-1 5-200 1.5 20 1.50:1/1.50:1 ±0.8dB ±8°
PL11-23/S 490-510 1.5 18 1.50:1/1.50:1 ±1.0dB N/A
PL12-1/NF 1-100 1.2 25 1.40:1/1.40:1 ±0.2dB ±3°
PL12-12 1-500 2.0 20 1.50:1/1.50:1 ±0.5dB ±5°
PL12-1/BF 2-100 1.5 25 1.40:1/1.40:1 ±0.2dB ±4°
PL12-1 5-100 1.2 25 1.40:1/1.40:1 ±0.3dB ±3°
PL12-8 5-1500 4.8 18 1.70:1/1.70:1 ±0.6dB ±10°
PL12-7 10-500 1.6 20 1.40:1/1.40:1 ±0.3dB ±4°
PL12-2 20-500 1.7 25 1.40:1/1.40:1 ±0.5dB ±6°
PL12-2/BF 20-500 1.7 25 1.40:1/1.40:1 ±0.3dB ±4°
PL12-2/NF 20-500 1.7 25 1.40:1/1.40:1 ±0.3dB ±4°
PL12-6 50-500 12 16 1.40:1/1.20:1 ±0.7dB ±10°
PL12-6/NF 50-500 12 16 1.40:1/1.20:1 ±0.7dB ±10°
PL12-5 20-1500 3.6 20 2.20:1/2.20:1 ±0.7dB ±11°
PL12-5/NF 25-1500 3.6 20 2.20:1/2.20:1 ±0.7dB ±11°
PL12-19 50-1000 14 14 1.35:1/1.25:1 ±1.4dB ±23°
PL12-3 100-1000 2.4 25 1.50:1/1.50:1 ±0.6dB ±8°
PL12-3/NF 100-1000 2.4 25 1.40:1/1.40:1 ±0.4dB ±8°
PL12-21 500-700 3.9 16 2.20:1/2.20:1 ±1.0dB ±11°
PL12-4 500-1500 3.5 20 2.20:1/2.20:1 ±0.6dB ±9°
PL12-4/NF 500-1500 3.5 20 1.40:1/1.40:1 ±0.6dB ±9°
PL12-14 800-1500 3.5 18 1.40:1/1.40:1 ±0.6dB ±10°
Contact Manufacturer For Other Specifications
16-WAY DIVIDER/COMBINER
16- WAY
PART NUMBER
FREQUENCY RANGE
(MHz)
INSERTION LOSS
(dB) Max.
ISOLATION (dB)
Min.
VSWR
In/Out
Max.
AMPLITUDE
BALANCE
Max.
PHASE
BALANCE
Max.
PL16-10 0.01-30 1.2 25 1.40:1/1.40:1 ±0.2dB ±3°
PL16-10/NF 0.01-30 1.2 25 1.40:1/1.40:1 ±0.2dB ±3°
PL16-11 0.5-125 1.2 20 1.40:1/1.40:1 ±0.3dB ±5°
PL16-11/NF 0.5-125 1.2 20 1.40:1/1.40:1 ±0.3dB ±5°
PL16-1 1-100 1.4 20 1.40:1/1.40:1 ±0.5dB ±8°
PL16-2 1-200 1.4 20 1.40:1/1.40:1 ±0.5dB ±8°
PL16-2-B-75 1-200 1.4 20 1.40:1/1.40:1 ±0.5dB ±8°
PL16-12 1-500 2.0 20 1.50:1/1.50:1 ±0.6dB ±10°
PL16-12/NF 1-500 2.0 20 1.50:1/1.50:1 ±0.6dB ±10°
PL16-19 5-1000 4.3 15 1.35:1/1.35:1 ±1.8dB ±20°
PL16-4-75/BF 10-500 3.8 16 1.50:1/1.45:1 ±1.25dB ±9°
PL16-4E-75/BF 10-500 3.7 16 1.50:1/1.45:1 ±1.25dB ±9°
PL16-5-75/BF 10-800 5.5 16 1.55:1/1.55:1 ±1.25dB ±9°
PL16-5E-75/BF 10-800 5.3 16 1.55:1/1.50:1 ±1.25dB ±10°
PL16-3/NF 20-1500 5.0 18 1.60:1/1.60:1 ±0.6dB ±10°
PL16-13 20-1600 5.0 18 1.60:1/1.60:1 ±0.6dB ±10°
PL16-20 50-100 1.8 20 1.50:1/1.50:1 ±0.5dB ±8°
PL16-14 200-2000 8.0 16 1.80:1/1.80:1 ±0.8dB ±12°
PL16-14/NF 200-2000 8.0 16 1.80:1/1.80:1 ±0.8dB ±12°
Contact Manufacturer For Other Specifications
32-WAY DIVIDER/COMBINER
36-WAY
PART NUMBER
FREQUENCY RANGE
(MHz)
INSERTION LOSS
(dB) Max.
ISOLATION (dB)
Min.
VSWR
In/Out
Max.
AMPLITUDE
BALANCE
Max.
PHASE
BALANCE
Max.
PL32-10 0.01-30 1.5 22 1.50:1/1.50:1 ±0.3dB ±5°
PL32-11 0.05-100 1.6 20 1.50:1/1.50:1 ±0.5dB ±9°
PL32-2 1-200 1.8 20 1.60:1/1.60:1 ±0.8dB ±12°
PL32-12 1-500 3.0 18 1.80:1/1.80:1 ±0.8dB ±15°
PL32-4-75/BF 10-500 4.8 16 1.50:1/1.45:1 ±1.5dB ±12°
PL32-4E-75/BF 10-500 4.6 16 1.50:1/1.45:1 ±1.5dB ±12°
PL32-5-75/BF 10-800 6.8 16 1.55:1/1.50:1 ±1.5dB ±12°
PL32-5E-75/BF 10-800 6.5 16 1.55:1/1.50:1 ±1.5dB ±12°
Contact Manufacturer For Other Specifications